The atypical startup characteristics of a pump as turbine

Abstract A generalized Euler equation of pump as turbine is derived, and the transient hydraulic performance of a centrifugal pump as turbine during an atypical startup period is measured. Meanwhile, the dimensionless analysis and the additional theoretical head calculation are also conducted. It is...

Full description

Bibliographic Details
Main Authors: Yu‐Liang Zhang, Yan‐Juan Zhao
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Energy Science & Engineering
Subjects:
Online Access:https://doi.org/10.1002/ese3.1014