Surface charge accumulation of post insulator: Dominant charge transition under different conditions

Abstract An insulator surface charge may be responsible for flashover along the insulator surface. In this study, experimental investigations of post insulator surface charge are performed using a variety of voltage, gas type, and gas pressure conditions. Combining the model of surface charge transp...

Full description

Bibliographic Details
Main Authors: Fangwei Liang, Feng Wang, She Chen, Qiuqin Sun, Lipeng Zhong
Format: Article
Language:English
Published: Wiley 2023-12-01
Series:High Voltage