Improved design of passive damping for single phase grid‐connected LCL filtered inverter considering impedance stability

Abstract Grid‐connected inverters with an inductor–capacitor–inductor (LCL) filter usually require the implementation of damping in the filter to suppress the resonance associated with the filter and hence ensure internal stability. The value for the damping resistor is commonly chosen as one‐third...

Full description

Bibliographic Details
Main Authors: Ramy Ali, Hamed Heydari‐doostabad, Shahab Sajedi, Terence O'Donnell
Format: Article
Language:English
Published: Wiley 2024-03-01
Series:IET Power Electronics