Late leaflet dehiscence in a bovine bioprosthesis-mimicked COVID-19 infection
Symptoms mimicking COVID-19 infection, pulmonary emboli, or septicemia delayed diagnosis of aortic bioprosthesis failure. A 71-year-old man was admitted emergently with shortness of breath, fever, cough, and chest pain. Echocardiography performed after 2 days showed diastolic regurgitation in an aor...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2021-09-01
|
Series: | SAGE Open Medical Case Reports |
Online Access: | https://doi.org/10.1177/2050313X211048039 |