The Effect of the Position Determination Error for Flexible Linear Array Elements on the Tomogram Focusing

In the article, the study of the quality of tomogram focusing during the inspection of objects with curved surfaces by flexible acoustic array was described. The main goal of the study was theoretically and experimentally define the acceptable deviation limits of the elements’ coordinates values. Th...

Full description

Bibliographic Details
Main Authors: Dmitry A. Sednev, Alexey I. Soldatov, Andrey A. Soldatov, Maria A. Kostina, Daria A. Koneva
Format: Article
Language:English
Published: MDPI AG 2023-05-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/23/10/4757