Simple transscleral fixation of IOL technique without tying up haptics

AIM: To introduce a novel technique for transscleral fixation of the posterior chamber intraocular lens (PC-IOL) that requires no sutures on the IOL haptics. METHODS: Instead of suturing polypropylene onto the IOL haptics, the method simply winds the thread on the haptics. Fifteen eyes of 15 patien...

Full description

Bibliographic Details
Main Authors: Junsung Lee, Jae-Yong Jang, Yong-Sok Ji
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2020-07-01
Series:International Journal of Ophthalmology
Subjects: