Diaphragm thickness modifications and associated factors during VA-ECMO for a cardiogenic shock: a cohort study

Abstract Background The incidence, causes and impact of diaphragm thickness evolution in veno-arterial extracorporeal membrane oxygenation (VA-ECMO) for cardiogenic shock are unknown. Our study investigates its evolution during the first week of VA-ECMO and its relationship with sweep gas flow setti...

Full description

Bibliographic Details
Main Authors: Pierre-Henri Moury, Alexandre Béhouche, Sébastien Bailly, Zoé Durand, Géraldine Dessertaine, Angelina Pollet, Samir Jaber, Samuel Verges, Pierre Albaladejo
Format: Article
Language:English
Published: SpringerOpen 2024-03-01
Series:Annals of Intensive Care
Subjects:
Online Access:https://doi.org/10.1186/s13613-024-01264-8