Developing FEM Procedures for Four-Sided Structural Sealant Glazing Curtain Wall Systems with Reentrant Corners

In the cyclic racking evaluation of curtain wall systems, physical testing with instrumentation is the standard method for collecting performance data by most design professionals. The resulting testing of full-scale mockups can provide many types of data, including load and displacement values at d...