Comparison between Oil and Water System Due to Power Failure in Pumping Station

In this paper, the power failure in a pumping system has been studied for different flow (Water and Oil). The transient flow rate and head of water and oil had been calculated at different section and effect of fluid properties had been studied. A computer program (Oil Hammer) was developed to solv...

Full description

Bibliographic Details
Main Author: Muhammad Asmail Eleiwi
Format: Article
Language:Arabic
Published: Mustansiriyah University/College of Engineering 2008-09-01
Series:Journal of Engineering and Sustainable Development