Lower-Bound Solution of Foundation-Bearing Capacity under Circular Uniformly Distributed Load

The semispatial static allowable stress field was constructed by three-dimensional stress columns, and the analytical lower-bound solution of bearing capacity of Mohr–Coulomb foundation beneath circular uniformly distributed load was put forward for the first time. The influence of the amount of str...

Full description

Bibliographic Details
Main Authors: Fang Wei, Wang Jiao, Zhang Wan-dongxing, Shi Li-jun
Format: Article
Language:English
Published: Hindawi Limited 2020-01-01
Series:Advances in Civil Engineering