Computational Evaluation Method for Inception Flowrate of Unstable Characteristic in Mixed Flow Pumps
To predict unstable characteristic of mixed flow pump, two mixed flow pumps were experimentally and numerically investigated. Calculated characteristics agreed well with experimental ones. It was clarified from the numerical results that stall mechanism was different between two impellers. One was t...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
The Japan Society of Mechanical Engineers
2010-03-01
|
Series: | Journal of Fluid Science and Technology |