Experimental Validation of Flow Uniformity Improvement by a Perforated Plate in the Heat Exchanger of SFR Steam Generator

The steam generator in a nuclear power plant is a type of heat exchanger in which heat transfer occurs from the hot fluid in multiple channels to the cold fluid. Therefore, a uniform flow over multiple channels is necessary to improve heat exchanger efficiency. The study aims at experimentally inves...

Full description

Bibliographic Details
Main Authors: Myung-Ho Kim, Van Toan Nguyen, Sunghyuk Im, Yohan Jung, Sun-Rock Choi, Byoung-Jae Kim
Format: Article
Language:English
Published: MDPI AG 2021-09-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/18/5846