Coordinated control for harmonic mitigation of parallel voltage-source inverters

The increasing use of power electronic devices can deteriorate the power quality by introducing voltage and current harmonics. In islanded microgrids, the presence of nonlinear loads can distort the point of common coupling (PCC) voltage, while the dead-time effect can also bring additional circulat...

Full description

Bibliographic Details
Main Authors: Yang Qi, Jingyang Fang, Jiazhe Liu, Yi Tang
Format: Article
Language:English
Published: China Electrotechnical Society 2018-09-01
Series:CES Transactions on Electrical Machines and Systems