A Case of Paracentral Corneal Perforation Treated with One-Bite Mini-Keratoplasty

A 61-year-old man presented with corneal perforation of 1.0 mm in diameter in his right eye caused by a metallic foreign body fragment. We used the “one-bite mini-keratoplasty” technique, which uses a cornea patch with a single host-graft-host suture to stop aqueous humor leakage. Postoperatively, t...