Use of a preoperative 3D templating and proximal lateral tibial fitting patient-specific instrumentation in fixed valgus complex primary total knee arthroplasty for a patient with retaining hardware for internal fixation to treat Schatzker type V tibial plateau fracture: A case report
A 72-year-old female patient with a fixed valgus knee deformity due to a Schatzker type V tibial plateau fracture treated with bilateral locking plates 8 years ago was admitted to our clinic with complaints of chronic pain and knee instability when walking. Radiographs revealed Kellgren–Lawrence Cla...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2023-11-01
|
Series: | SAGE Open Medical Case Reports |
Online Access: | https://doi.org/10.1177/2050313X231215217 |