Towards joint in situ determination of pressure and temperature in the large volume press exclusively from X-ray diffraction

Since high-pressure devices have been used at synchrotron facilities, accurate determination of pressure and temperature in the sample has been a crucial objective, particularly for experiments that simulate the Earth's interior. However, in some cases using a thermocouple may have a high likel...