Microfluidic chip combined with magnetic-activated cell sorting technology for tumor antigen-independent sorting of circulating hepatocellular carcinoma cells
Purpose We aimed to generate a capture platform that integrates a deterministic lateral displacement (DLD) microfluidic structure with magnetic-activated cell sorting (MACS) technology for miniaturized, efficient, tumor antigen-independent circulating tumor cell (CTC) separation. Methods The microfl...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
PeerJ Inc.
2019-04-01
|
Series: | PeerJ |
Subjects: | |
Online Access: | https://peerj.com/articles/6681.pdf |