System for magnetic monitoring of high voltage motors MM6212

This paper suggests the possibility of diagnosing different types of failure in working induction motors using a device for spectral analysis of axial leakage flux, which has been developed by the Electrotechnical Institute Nikola Tesla. A search coil, which can be of different diameters, was mounte...

Full description

Bibliographic Details
Main Authors: Kartalović Nenad, Babić Blagoje, Ilić Nikola, Cakić Nikola, Milosavljević Srđan
Format: Article
Language:English
Published: Electrical Engineering Institute Nikola Tesla 2012-01-01
Series:Zbornik Radova: Elektrotehnički Institut "Nikola Tesla"
Subjects:
Online Access:http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2012/0350-85281222251K.pdf