PROVIDING THE THERMAL RELIABILITY OF WINDOW JUNCTIONS DURING THE THERMAL MODERNIZATION OF CIVIL BUILDINGS

In order to assess the possibility of condensation on an internal window jamb surface, the temperature fields of window junctions to brick and precast concrete walls of civil buildings were analyzed, which were massively produced in the second half of the twentieth century. This study obtained the d...

Full description

Bibliographic Details
Main Authors: Mykola Pashynskyi, Stanislav Dzhyrma, Victor Pashynskyi, Vladislav Nastoyashchiy
Format: Article
Language:English
Published: Faculty of Civil Engineering Osijek 2021-01-01
Series:e-GFOS
Subjects:
Online Access:http://e-gfos.gfos.hr/app/storage/protected/04-01-2021-19-22-49-egfos-2020-21-4.pdf