An analysis of the resistance of an extended end-plate beam-to-beam connection subjected to tension in fire conditions

This paper presents an analysis of the fire resistance of a steel joint subject-ed to tension. The authors of this article used prescriptive rules and simple calculation models to present an impact of the value of the load on the fire resistance of the connection. Designers often evaluate the critic...

Full description

Bibliographic Details
Main Authors: Alina Słowikowska, Łukasz Polus
Format: Article
Language:English
Published: Lublin University of Technology 2019-08-01
Series:Budownictwo i Architektura
Subjects:
Online Access:https://ph.pollub.pl/index.php/bia/article/view/225