Influence of surface discharge on the deterioration characteristics of ethylene‐propylene rubber cable insulation under alternating current high voltage

Abstract To investigate partial discharge‐induced deterioration characteristics of ethylene‐propylene rubber (EPR) cable insulation under repeated alternating current (AC) voltage on high‐speed trains, an experimental platform with a column‐plate EPR insulation model is established. The surface cond...

Full description

Bibliographic Details
Main Authors: Longlei Bai, Daoping Fan, Tianhe Li, Bing Li, Mingwei Su, Shaogui Fan, Liuzhong Zhang
Format: Article
Language:English
Published: Wiley 2022-07-01
Series:IET Science, Measurement & Technology
Online Access:https://doi.org/10.1049/smt2.12104