Glycemic control in children with type 1 diabetes treated with the advanced hybrid closed loop system 2-year prospective, observational, two-center study

Background and aimsMiniMed 780G is the first Advanced Hybrid Closed Loop (AHCL) system in Poland, approved in the EU in 2020. To date, observations of glycemic control up to 12 months have been published. This study aimed to analyze glycemic control and anthropometric parameters in children and adol...

Full description

Bibliographic Details
Main Authors: Sebastian Seget, Agata Chobot, Mateusz Tarasiewicz, Anna Bielawska, Ewa Rusak, Agnieszka Ochab, Joanna Polanska, Przemysława Jarosz-Chobot
Format: Article
Language:English
Published: Frontiers Media S.A. 2024-02-01
Series:Frontiers in Endocrinology
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fendo.2024.1332418/full