Effects of highly preheated combustion air on characteristics of burner operation and fuel consumption in controlled-air incinerator

A experiment was conducted in a laboratory scale controlled-air incinerator in to observe the effect of secondary combustion air temperature to secondary burner operation and its fuel consumption. Sawdust was partially burned in a primary combustion chamber while feeding with primary air at 30% of s...

Full description

Bibliographic Details
Main Authors: Pitaksa Suvarnakuta, Suthum Patumsawad, Somrat Kerdsuwan
Format: Article
Language:English
Published: Prince of Songkla University 2008-01-01
Series:Songklanakarin Journal of Science and Technology (SJST)
Subjects:
Online Access:http://www.sjst.psu.ac.th/ejournal/journal/30-1/0125-3395-30-1-125-129.pdf