Comparative Study of Shell and Helically-Coiled Tube Heat Exchangers with Various Dimple Arrangements in Condensers for Odor Control in a Pyrolysis System

This study performed evaluations of the shell and helically-coiled tube heat exchangers with various dimple arrangements, that is, flat, inline, staggered, and bulged, at different Dean numbers (De) and inlet temperatures of a hot channel. Conjugated heat transfer was analyzed to evaluate the heat t...

Full description

Bibliographic Details
Main Authors: Sun-Min Kim, Jun-Ho Jo, Ye-Eun Lee, Yeong-Seok Yoo
Format: Article
Language:English
Published: MDPI AG 2016-12-01
Series:Energies