Performance enhancement of the motorcycle exhaust thermoelectric generator - Optimization of the hot-side heat exchanger configuration
The article investigates the influences of three structural parameters of the hot-side heat exchanger (HHE), including the fin quantity, height, and thickness on the mean temperature of its base. The HHE is integrated into the thermoelectric generator unit (TGU), which uses motorcycle exhaust gas as...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2023-11-01
|
Series: | Case Studies in Thermal Engineering |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2214157X2300922X |