Effect of Particle Migration on the Stress Field in Microfluidic Flows of Blood Analog Fluids at High Reynolds Numbers

In the present paper, we investigate how the reductions in shear stresses and pressure losses in microfluidic gaps are directly linked to the local characteristics of cell-free layers (CFLs) at channel Reynolds numbers relevant to ventricular assist device (VAD) applications. For this, detailed stud...

Full description

Bibliographic Details
Main Authors: Finn Knüppel, Ang Sun, Frank-Hendrik Wurm, Jeanette Hussong, Benjamin Torner
Format: Article
Language:English
Published: MDPI AG 2023-07-01
Series:Micromachines
Subjects:
Online Access:https://www.mdpi.com/2072-666X/14/8/1494