Tracking error analysis method of digital pulse power supply for heavy ion accelerator based on emd reconstruction
Assessment of the state of a pulse power supply requires effective and accurate methods to measure and reconstruct the tracking error. This paper proposes a tracking error measurement method for a digital pulse power supply. A de-noising algorithm based on Empirical Mode Decomposition (EMD) is used...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Polish Academy of Sciences
2020-06-01
|
Series: | Metrology and Measurement Systems |
Subjects: | |
Online Access: | http://journals.pan.pl/dlibra/publication/132779/edition/116017/content |