Non Vascularised Fibula Strut Graft Augmentation for Fixation of Proximal Humerus 3-Part Fracture using PHILOS Plate and CC Screws in a Young Male

Proximal humerus fracture accounts for 4-5% of all fractures. Locking Compression Plate (LCP) Proximal Humerus Internal Locking System (PHILOS) fixation is currently the most widely used method for the management of unstable proximal humerus fractures. LCP system of the proximal humerus is better...