Analytical modelling of salient pole synchronous generators under eccentricity faults by including stator slotting effect

Abstract Here, a dynamic analytical model is provided for salient pole synchronous generators (SPSGs) under different eccentricity faults. A useful technique is developed first to describe the rotor position‐dependent non‐uniform air gap distribution by a proper function in the healthy state, which...