Clutch and Brake Related Testing of Magnetorheological Fluids Using the Basf Twin Gap Magnetocell
A new magnetocell, based on a plate-plate twin gap with housing and integrated online flux density measurement, allows for a reliable rheological characterization of magneto¬rheological fluids (MRF). Various modifications introduced into the commercial magnetocell version MRD180/1T (Physica/Anton Pa...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
De Gruyter
2010-08-01
|
Series: | Applied Rheology |
Subjects: | |
Online Access: | https://doi.org/10.3933/applrheol-20-41778 |