A Modified Calculation Method for a Centered Water Nozzle Steam–Water Injector
A centered water nozzle steam–water injector is driven by cold water to pump steam at a low pressure and to produce a high outlet water pressure. It can be used as a safety pump in a light water reactor to inject cooling water into the reactor core with no power supply in case of an accident. In thi...