Detection of Broken Rotor Bars in a Cage Induction Machine Using DC Injection Braking

In this paper, an effective procedure for broken rotor bar (BRB) fault detection in a three-phase squirrel-cage induction machine (SCIM) is proposed. This approach relies on a motor current signature analysis (MCSA) by observing the specific fault-related current component generated by applying the...

Full description

Bibliographic Details
Main Authors: Dejan G. Jerkan, Dejan Reljic, Ivan Todorovic, Ivana Isakov, Vlado Porobic, Drazen Dujic
Format: Article
Language:English
Published: IEEE 2022-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9770817/