Reactor dynamic simulation to analyze possible scenarios after a spurious opening of the safety flapper valve of TRR during the normal operation regarding the inherently safety features and Design Extension Conditions (DEC) by using the RELAP5 code

LOFA is one of the most important PIE in nuclear reactors. For the pool-type research reactor, the safety flapper valve is usually located below the reactor core and have a very important rule on the reactor safety especially during the loss of the pump accident. In this paper, TRR has been simulate...

Full description

Bibliographic Details
Main Author: Afshin Hedayat
Format: Article
Language:English
Published: KeAi Communications Co., Ltd. 2021-01-01
Series:International Journal of Advanced Nuclear Reactor Design and Technology
Subjects: