IMPROVED MODELS AND METHOD OF POWER CHANGE OF NPP UNIT WITH VVER-1000

This study represents the improved mathematical and imitational allocated in space multi-zone model of VVER-1000 which differs from the known one. It allows to take into account the energy release of 235U nuclei fission as well as 239Pu . Moreover, this model includes sub-models of simultaneous cont...

Full description

Bibliographic Details
Main Authors: T. Foshch, S. Pelykh
Format: Article
Language:English
Published: Odessa National Academy of Food Technologies 2017-06-01
Series:Автоматизация технологических и бизнес-процессов
Subjects:
Online Access:http://journals.gsjp.eu/index.php/atbp/article/view/505