Effect of the Volumetric Flow Rate Measurement Methodology of Positive Pressure Ventilators on the Parameters of the Drive Unit
The nature and conditions of the execution of tests (open or duct flow) in terms of evaluating the flow rate generated by positive pressure ventilators (PPV) may affect the parameters of the drive unit recorded during testing. In this article, popular PPVs (conventional type—W1 and turbo type—W2) of...