Separate and integral effect tests of aerosol retention in steam generator during tube rupture accident
A steam generator tube rupture accompanying a core damage may cause the fission product to be released to environment bypassing the containment. In such an accident, the steam generator is the major path of the radioactive aerosol release.AEOLUS facility, the scaled-down model of Korean type steam g...