Test Research on Continued Exhaust Fault of Safety Valve Used in Pressure Reducer

The integrated pressure reducer used in an oxygen system of certain aircraft has experienced continuous deflation failure of the low-pressure safety valve for many times in the process of use.In order to analyze the cause of the failure,the test is designed and performed according to the configurati...

Full description

Bibliographic Details
Main Authors: FENG Wenchun, LI Yao, ZHU Yongfeng, LIU Zhonghua
Format: Article
Language:zho
Published: Editorial Department of Advances in Aeronautical Science and Engineering 2022-08-01
Series:Hangkong gongcheng jinzhan
Subjects:
Online Access:http://hkgcjz.cnjournals.com/hkgcjz/article/abstract/2021170