Direct surface wetting sprinkler system to reduce the use of evaporative cooling pads in meat chicken production: indoor thermal environment, water usage, litter moisture content, live market weights, and mortalities

An overhead sprinkler system that directly applies water onto meat chickens in tunnel ventilated houses was evaluated and compared with a conventional evaporative cooling pad system at 2 commercial farms in south-eastern Queensland, Australia. The sprinkler system was used to reduce the use of evapo...

Full description

Bibliographic Details
Main Authors: Mark W. Dunlop, Jim McAuley
Format: Article
Language:English
Published: Elsevier 2021-05-01
Series:Poultry Science
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S0032579121001127
_version_ 1830176911761866752
author Mark W. Dunlop
Jim McAuley
author_facet Mark W. Dunlop
Jim McAuley
author_sort Mark W. Dunlop
collection DOAJ
description An overhead sprinkler system that directly applies water onto meat chickens in tunnel ventilated houses was evaluated and compared with a conventional evaporative cooling pad system at 2 commercial farms in south-eastern Queensland, Australia. The sprinkler system was used to reduce the use of evaporative cooling pads as the primary cooling system but not replace evaporative cooling pads altogether. The sprinkler system used low water pressure and comprised evenly spaced sprinklers and a programmable controller. Water was applied intermittently based on house temperature and a temperature program that was related to bird age. The study was conducted over 6 sequential grow-outs during a 1-year period. Air temperature, relative humidity, litter moisture content, cooling water usage, live market weight, and mortality were assessed during the study. The effect of sprinklers on these measured parameters was complicated by interactions with farm, batch, bird age, and time of day. We found that, in general, houses with combined sprinkler and evaporative cooling pad systems used less water, while having similar litter moisture content, live market weight, and mortality compared with control houses that were fitted with conventional evaporative cooling pads. When evaporative cooling was required, sprinkler houses had warmer air temperature but lower relative humidity than the control houses. Bird comfort due to the direct cooling effect of water evaporating off the birds was not directly assessed during this study but was inferred from thermal camera images and from live weight and mortality data. This was the first study in Australia involving this sprinkler system, and we suggest that the sprinkler system design and operation may require some adaptation to better suit Australian poultry house design and climatic conditions, including the need for additional sprinklers to improve coverage, lower set-point temperatures, and altering sprinkler spacing to suit ceiling baffle curtains (if fitted).
first_indexed 2024-12-17T19:15:00Z
format Article
id doaj.art-f82e33948c3f442493b63be5c93fc121
institution Directory Open Access Journal
issn 0032-5791
language English
last_indexed 2024-12-17T19:15:00Z
publishDate 2021-05-01
publisher Elsevier
record_format Article
series Poultry Science
spelling doaj.art-f82e33948c3f442493b63be5c93fc1212022-12-21T21:35:47ZengElsevierPoultry Science0032-57912021-05-011005101078Direct surface wetting sprinkler system to reduce the use of evaporative cooling pads in meat chicken production: indoor thermal environment, water usage, litter moisture content, live market weights, and mortalitiesMark W. Dunlop0Jim McAuley1Corresponding author:; Department of Agriculture and Fisheries, Queensland Government, Toowoomba Qld 4350, AustraliaDepartment of Agriculture and Fisheries, Queensland Government, Toowoomba Qld 4350, AustraliaAn overhead sprinkler system that directly applies water onto meat chickens in tunnel ventilated houses was evaluated and compared with a conventional evaporative cooling pad system at 2 commercial farms in south-eastern Queensland, Australia. The sprinkler system was used to reduce the use of evaporative cooling pads as the primary cooling system but not replace evaporative cooling pads altogether. The sprinkler system used low water pressure and comprised evenly spaced sprinklers and a programmable controller. Water was applied intermittently based on house temperature and a temperature program that was related to bird age. The study was conducted over 6 sequential grow-outs during a 1-year period. Air temperature, relative humidity, litter moisture content, cooling water usage, live market weight, and mortality were assessed during the study. The effect of sprinklers on these measured parameters was complicated by interactions with farm, batch, bird age, and time of day. We found that, in general, houses with combined sprinkler and evaporative cooling pad systems used less water, while having similar litter moisture content, live market weight, and mortality compared with control houses that were fitted with conventional evaporative cooling pads. When evaporative cooling was required, sprinkler houses had warmer air temperature but lower relative humidity than the control houses. Bird comfort due to the direct cooling effect of water evaporating off the birds was not directly assessed during this study but was inferred from thermal camera images and from live weight and mortality data. This was the first study in Australia involving this sprinkler system, and we suggest that the sprinkler system design and operation may require some adaptation to better suit Australian poultry house design and climatic conditions, including the need for additional sprinklers to improve coverage, lower set-point temperatures, and altering sprinkler spacing to suit ceiling baffle curtains (if fitted).http://www.sciencedirect.com/science/article/pii/S0032579121001127broilerpoultrysprinklerwater efficiencyrelative humidity
spellingShingle Mark W. Dunlop
Jim McAuley
Direct surface wetting sprinkler system to reduce the use of evaporative cooling pads in meat chicken production: indoor thermal environment, water usage, litter moisture content, live market weights, and mortalities
Poultry Science
broiler
poultry
sprinkler
water efficiency
relative humidity
title Direct surface wetting sprinkler system to reduce the use of evaporative cooling pads in meat chicken production: indoor thermal environment, water usage, litter moisture content, live market weights, and mortalities
title_full Direct surface wetting sprinkler system to reduce the use of evaporative cooling pads in meat chicken production: indoor thermal environment, water usage, litter moisture content, live market weights, and mortalities
title_fullStr Direct surface wetting sprinkler system to reduce the use of evaporative cooling pads in meat chicken production: indoor thermal environment, water usage, litter moisture content, live market weights, and mortalities
title_full_unstemmed Direct surface wetting sprinkler system to reduce the use of evaporative cooling pads in meat chicken production: indoor thermal environment, water usage, litter moisture content, live market weights, and mortalities
title_short Direct surface wetting sprinkler system to reduce the use of evaporative cooling pads in meat chicken production: indoor thermal environment, water usage, litter moisture content, live market weights, and mortalities
title_sort direct surface wetting sprinkler system to reduce the use of evaporative cooling pads in meat chicken production indoor thermal environment water usage litter moisture content live market weights and mortalities
topic broiler
poultry
sprinkler
water efficiency
relative humidity
url http://www.sciencedirect.com/science/article/pii/S0032579121001127
work_keys_str_mv AT markwdunlop directsurfacewettingsprinklersystemtoreducetheuseofevaporativecoolingpadsinmeatchickenproductionindoorthermalenvironmentwaterusagelittermoisturecontentlivemarketweightsandmortalities
AT jimmcauley directsurfacewettingsprinklersystemtoreducetheuseofevaporativecoolingpadsinmeatchickenproductionindoorthermalenvironmentwaterusagelittermoisturecontentlivemarketweightsandmortalities