VxG Pattern-Based Analysis and Battery Deterioration Diagnosis
This paper presents the results of an analysis using the direct current internal resistance (DCIR) method on a nickel-cobalt-manganese oxide (NCM)-based battery with a nominal capacity of 55.6 Ah. The accelerated degradation test was performed on V0G, V1G, and V2G patterns, representing existing sim...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-08-01
|
Series: | Energies |
Subjects: | |