Study of Heat Pipe Thermal Performance with Internal Modified Geometry

The aim of this study was to investigate the effect of inserting a new internal tube packing (TP) on the thermal performance of a thermosyphon heat pipe (THP). The THP pipe was made from copper with an inner diameter of 17.4 mm and length of 600 mm. The new internal tube packing (TP) had a central c...

Full description

Bibliographic Details
Main Authors: Alaa A. B. Temimy, Adnan A. Abdulrasool, F. A. Hamad
Format: Article
Language:English
Published: MDPI AG 2021-06-01
Series:Fluids
Subjects:
Online Access:https://www.mdpi.com/2311-5521/6/7/231