Mathematical Modeling of Postcombustion in an Electric Arc Furnace (EAF)

Numerical modeling was used to study the capability of postcombustion in an electric arc furnace (EAF) equipped with virtual lance burners. The CO flow rate at the molten bath surface was estimated using the off-gas data obtained close to the outlet of an EAF. Then, the effect of the secondary oxyge...

Full description

Bibliographic Details
Main Authors: Niloofar Arzpeyma, Mikael Ersson, Pär G. Jönsson
Format: Article
Language:English
Published: MDPI AG 2019-05-01
Series:Metals
Subjects:
Online Access:https://www.mdpi.com/2075-4701/9/5/547