Effectiveness-mass transfer units (ε-MTU) model of a reverse osmosis membrane mass exchanger

A strong analogy exists between heat exchangers and osmotic mass exchangers. The effectiveness-number of transfer units (ε-NTU) method is well-known for the sizing and rating of heat exchangers. A similar method, called the effectiveness-mass transfer units (ε-MTU) method, is developed for reverse o...