Feasibility Study for Elimination of the Screening Current-Induced Fields in HTS Coil

Herein, we report a feasibility study for elimination of the screening current-induced field (SCIF) in fully insulated (INS) and no-insulation (NI) GdBCO coated conductor (CC) coils exposed to an external AC magnetic field generated by background solenoid copper coils. Prior to investigating the eff...

Full description

Bibliographic Details
Main Authors: Kazikawa, K., Kim, K. L., Choi, Y. H., Kim, Y. G., Kang, D. H., Lee, H. G., Hahn, Seung-Yong
Other Authors: Francis Bitter Magnet Laboratory (Massachusetts Institute of Technology)
Format: Article
Language:English
Published: Springer US 2016
Online Access:http://hdl.handle.net/1721.1/105214