Feasibility Study for Elimination of the Screening Current-Induced Fields in HTS Coil
Herein, we report a feasibility study for elimination of the screening current-induced field (SCIF) in fully insulated (INS) and no-insulation (NI) GdBCO coated conductor (CC) coils exposed to an external AC magnetic field generated by background solenoid copper coils. Prior to investigating the eff...
Main Authors: | Kazikawa, K., Kim, K. L., Choi, Y. H., Kim, Y. G., Kang, D. H., Lee, H. G., Hahn, Seung-Yong |
---|---|
Other Authors: | Francis Bitter Magnet Laboratory (Massachusetts Institute of Technology) |
Format: | Article |
Language: | English |
Published: |
Springer US
2016
|
Online Access: | http://hdl.handle.net/1721.1/105214 |
Similar Items
-
Nonlinear Behavior of a Shim Coil in an LTS/HTS NMR Magnet With an HTS Insert Comprising Double-Pancake HTS-Tape Coils
by: Iwasa, Yukikazu, et al.
Published: (2010) -
Spatial and Temporal Variations of a Screening Current Induced Magnetic Field in a Double-Pancake HTS Insert of an LTS/HTS NMR Magnet
by: Ahn, Min Cheol, et al.
Published: (2010) -
Stress Analysis of a High Temperature Superconductor Coil Wound With Bi-2223/Ag Tapes for High Field HTS/LTS NMR Magnet Application
by: Kiyoshi, Tsukasa, et al.
Published: (2010) -
An Analytical Technique to Elucidate Field Impurities From Manufacturing Uncertainties of an Double Pancake Type HTS Insert for High Field LTS/HTS NMR Magnets
by: Iwasa, Yukikazu, et al.
Published: (2010) -
Study on Trapped Field Characteristics of HTS Bulk Annuli With Iron Rings for Ferromagnetic Shimming of a Compact NMR Magnet
by: Kim, Seok Beom, et al.
Published: (2010)