Initial results of tests of depth markers as a surface diagnostic for fusion devices
The Accelerator-Based In Situ Materials Surveillance (AIMS) diagnostic was developed to perform in situ ion beam analysis (IBA) on Alcator C-Mod in August 2012 to study divertor surfaces between shots. These results were limited to studying low-Z surface properties, because the Coulomb barrier precl...