Overview of first Wendelstein 7-X high-performance operation
The optimized superconducting stellarator device Wendelstein 7-X (with major radius R = 5.5 m, minor radius a = 0.5 m, and 30 m3 plasma volume) restarted operation after the assembly of a graphite heat shield and 10 inertially cooled island divertor modules. This paper reports on the results from th...
Main Authors: | , , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
IOP Publishing
2020
|