Investigation of the Fundamental Reliability Unit for Cu Dual-Damascene Metallization

An investigation has been carried out to determine the fundamental reliability unit of copper dual-damascene metallization. Electromigration experiments have been carried out on straight via-to-via interconnects in the lower metal (M1) and the upper metal (M2), and in a simple interconnect tree stru...

Full description

Bibliographic Details
Main Authors: Gan, C.L., Thompson, Carl V., Pey, Kin Leong, Choi, Wee Kiong, Wei, F., Hau-Riege, S.P., Augur, R., Tay, H.L., Yu, B., Radhakrishnan, M.K.
Format: Article
Language:en_US
Published: 2003
Subjects:
Online Access:http://hdl.handle.net/1721.1/3976