Drive train improvements and performance evaluation of a robotically steered needle
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.
Main Author: | |
---|---|
Other Authors: | |
Format: | Thesis |
Language: | eng |
Published: |
Massachusetts Institute of Technology
2012
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/68529 |
_version_ | 1826213854214881280 |
---|---|
author | Graves, Carmen Marten-Ellis |
author2 | Conor J. Walsh and Alexander H. Slocum. |
author_facet | Conor J. Walsh and Alexander H. Slocum. Graves, Carmen Marten-Ellis |
author_sort | Graves, Carmen Marten-Ellis |
collection | MIT |
description | Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. |
first_indexed | 2024-09-23T15:55:34Z |
format | Thesis |
id | mit-1721.1/68529 |
institution | Massachusetts Institute of Technology |
language | eng |
last_indexed | 2024-09-23T15:55:34Z |
publishDate | 2012 |
publisher | Massachusetts Institute of Technology |
record_format | dspace |
spelling | mit-1721.1/685292022-01-13T07:54:36Z Drive train improvements and performance evaluation of a robotically steered needle Graves, Carmen Marten-Ellis Conor J. Walsh and Alexander H. Slocum. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Department of Mechanical Engineering Mechanical Engineering. Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. Cataloged from PDF version of thesis. Includes bibliographical references (p. 49). The focus of this thesis is on the design and evaluation of a robust drive mechanism intended to robotically steer a thermal ablation electrode. The device is intended to enable more efficient kidney tumor ablation therapy guided by CT scanning. The steering mechanism is based on the concept of substantially straightening a pre-curved Nitinol stylet by retracting it into a concentric outer cannula, and re-deploying it at a different position. A drive mechanism was previously designed to actuate the cannula and stylet motions. While successfully demonstrating the concept, the previous prototype used a screw-spline mechanism that had a key and groove that were difficult to manufacture, assemble and align. To address the issue of the key being misaligned with the spline nut, an alternative, more robust means was considered for constraining the screw-spline from rotating. This was achieved through the design of a new profiled threaded shaft and nut that reduced the part count and simplified manufacturing and assembly. To determine the optimal parameters for the profile shape, an analytical expression was derived that related the tolerance between the nut and shaft to the angular backlash, which was validated using SolidWorks. A deterministic design process was then followed to size the actuators and transmissions for such drive mechanisms given a set of specifications for cannula/stylet force and speed. Specifically, the gear train was designed to ensure sufficient force for deploying a pre-curved needle from a cannula and into a gelatinous solid based on previously collected experimental data. Using this process, Faulhaber AM1524 micro-stepper motors with 15A planetary gearheads were selected that could provide 10 N and 20N of force to both the cannula and stylet (in line with the screws) at a speed of 7 mm/s. Accuracy and repeatability of the drive mechanism were measured in a bench-top experiment using calipers and a protractor and yielded sub-mm values for translation and approximately two degrees of play for rotation. Targeting experiments were also performed in ballistics gelatin and ex-vivo tissue samples where the distal tip of the stylet was recorded with a camera and CT scanner and demonstrated that the device is ready for testing with an integrated thermal ablation system. by Carmen Marten-Ellis Graves. S.B. 2012-01-12T19:34:59Z 2012-01-12T19:34:59Z 2011 2011 Thesis http://hdl.handle.net/1721.1/68529 770927713 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 60 p. application/pdf Massachusetts Institute of Technology |
spellingShingle | Mechanical Engineering. Graves, Carmen Marten-Ellis Drive train improvements and performance evaluation of a robotically steered needle |
title | Drive train improvements and performance evaluation of a robotically steered needle |
title_full | Drive train improvements and performance evaluation of a robotically steered needle |
title_fullStr | Drive train improvements and performance evaluation of a robotically steered needle |
title_full_unstemmed | Drive train improvements and performance evaluation of a robotically steered needle |
title_short | Drive train improvements and performance evaluation of a robotically steered needle |
title_sort | drive train improvements and performance evaluation of a robotically steered needle |
topic | Mechanical Engineering. |
url | http://hdl.handle.net/1721.1/68529 |
work_keys_str_mv | AT gravescarmenmartenellis drivetrainimprovementsandperformanceevaluationofaroboticallysteeredneedle |