Fire resistance of steel and composite columns

A programme of experimental testing has been conducted to investigate the behaviour of steel columns and concrete-encased steel section composite columns at elevated temperature. Heating is attained in an electric furnace. Measurements of internal forces, lateral deflections, axial displacements and...

Full description

Bibliographic Details
Main Author: Phng, Eugene Guan Hwee
Other Authors: Tan Kang Hai
Format: Thesis
Language:English
Published: 2008
Subjects:
Online Access:https://hdl.handle.net/10356/11980