Brushless synchronous generator turn-to-turn short circuit fault detection using multilayer neural network

Stator winding short circuit is one of the faults that occur frequently in electrical machines. Therefore, fault detection and elimination in electric drive systems is necessary for safety-critical applications in order not to cause catastrophic failure to the machine in a short time. This paper rev...

Full description

Bibliographic Details
Main Authors: Tun, Pyae Phyo, Kumar, Padmanabhan Sampath, Pratama, Ryan Arya, Liu, Shuyong
Other Authors: 2018 Asian Conference on Energy, Power and Transportation Electrification (ACEPT)
Format: Conference Paper
Language:English
Published: 2021
Subjects:
Online Access:https://hdl.handle.net/10356/146694